Panasonic EW-BW10W User Manual

Browse online or download User Manual for Health and hygiene Panasonic EW-BW10W. Panasonic EW-BW10W User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 27
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
Panasonic*
Operating Instructions
Instrucciones de Uso
Wrist Blood Pressure Monitor
Monitor de presión arteriai de muñeca
Modei No7№ de Modeio EW-BW10
English
Español S1
Before operating this device, piease read these instructions compieteiy and
save this manuai for future use.
Antes de utilizar este dispositivo, lea completamente estas instrucciones y
conserve este manual para futura referencia.
Page view 0
1 2 3 4 5 6 ... 26 27

Summary of Contents

Page 1 - Panasonic*

Panasonic*Operating InstructionsInstrucciones de UsoWrist Blood Pressure MonitorMonitor de presión arteriai de muñecaModei No7№ de Modeio EW-BW10Engli

Page 2 - 1 IJBIHil

I Inserting/Replacing Batteries*Always use alkaline batteries. (2 AAA-size LR03 alkaline batteries)• When replacing batteries, always use 2 fresh alka

Page 3 - I Table of Contents

For Batteries• The frequency of use for batteries is approximately 300 measurements (3 times per day) with fresh Panasonic alkaline batteries (AAA-siz

Page 4 - I Basics of Blood Pressure

I Fitting the Pressure Cuff (cont.)2. Firmly wrap and fasten using the hoop and loop fastener.• A loosely applied pressure cuff will result in high b

Page 5 - IJBIIH!! 4

I Obtaining Accurate MeasurementsAlways take your blood pressure at the same time while sitting In the same position and using the same wrist.It is re

Page 6

I Obtaining Accurate Measurements (cont.)Do not take measurements in the positions shown below as they wili be inaccurate.Do not bend your wrist inwar

Page 7

I Measuring Your Blood PressureFiSi Dis; ifisraaamdgwHR/f1R^SiS8DIA.•m^Bi |U| !► Pul;e v_4OFF/ONS№KT1. Place the arm to which the device is attache

Page 8 - 7* Classification

I Measuring Your Blood Pressure (cont.)Reading the blood pressure displayBlood pressure values for both systolic and diastolic readings are determined

Page 9 - I Diagram of the Device

Advice:In general, blood pressure measurements are lower on the second attempt because you are calmer.For people who easily get tense, measuring twice

Page 10 - 9 IJffllH!!

I Movement Detection FunctionIf movement is detected while measurement is being carried out and morepressure is applied by the pressure cuff, the rnar

Page 11 - I Fitting the Pressure Cuff

I Irregular Pulse FunctionIf the pulse rate varies by more than ±25 % from the average while a measurement is being taken, when measurement is complet

Page 12

Panasonic Oscillometric Automatic Wrist Blood Pressure Monitor Model EW-BW10 Is a device Intended to measure systolic and diastolic blood pressure and

Page 13 - IJglill 12

I Saving and Recalling DataSaving Readings• All data Is retained even when the batteries go flat or are changed.1. The M mark will flash after measure

Page 14 - 13 IJBIHil

Recalling Stored DataReadings can be recalled after being saved without having to first turn thedevice on.1 OFh 1 STA'WSYS. imH, DIA. imH:N3 вгA

Page 15 - IJgliil 14

I After UseStorage1. Fold the end of the pressure cuff in the direction of the arrow.2. Next, fold the pressure cuff in on itself and secure it on loo

Page 16 - 15 i^Pii

I SpecificationsPower source DC 3 V (2 /\/WLR03 size alkaline batteries)Display Digital LCDMethod of measurementOscillometric systemMeasurement range

Page 17

I Care and MaintenanceDo not attempt to disassemble, repair or modify the unit.• Doing so may cause fire or cause the unit to malfunction. It may also

Page 18 - I Movement Detection Function

I TroubleshootingDisplay Status before error Cause and solutionUOiisdisplayed.The indication disappears in the middle of the operation, (the ! 3 mark

Page 19 - I Irregular Pulse Function

I Troubleshooting (cont.)Symptom Possible causeBlood pressure is abnormally high or low.• The posture of the person is different each time measurement

Page 20 - I Saving and Recalling Data

For questions or assistance with your biood pressure monitor, cail us at 1-800-338-0552.Panasonic Corporation of North AmericaOne Panasonic Way, 1H-1S

Page 21 - IJgliil 20

I Table of ContentsIntroduction... 3Basics of Biood Pressure

Page 22 - I After Use

I IntroductionThank you for purchasing the Panasonic Automatic Wrist Biood Pressure Monitor EW-BW10.Measuring your own biood pressure is an important

Page 23 - I Specifications

I Important Instructions Before UseDo not confuse self-monitoring with self-diagnosis. Blood pressure measurements should only be interpreted by a hea

Page 24 - I Care and Maintenance

7.8.g.this is not possible, however, try to take measurements at a specified time prior to breakfast, and before you have become active. You should re

Page 25 - I Troubleshooting

g. Do not short-circuit batteries.h. Do not attempt to recharge the batteries inciuded with the unit.12. Piease remove the cuff if abnormai operation

Page 26 - I Troubleshooting (cont.)

Easily Check Your Blood Pressure Readings Against the JNC 7* ClassificationBlood Pressure Categories^ A0. (mmHg)OQ Q(00)£0. aooOQo1009080Stage 2 Hyper

Page 27 - 0 .4 EN, SP Printed in China

I Diagram of the Device* Only use alkaline batteries.BodyDisplayThis product includes:• Main unit• Storage case• Batteries• Operating Instructions• Gu