Taking a Reading
1. Press the Off/On Start button.
After the entire display has been lit, the cuff will be pressurized
and measurement will be taken automatically.
The pressure value, mark, and the time will be displayed.
The heart mark will flash when pulse is detected during
depressurization.
2. After the measurement is completed, the unit will beep, and
the blood pressure value and pulse rate will be displayed.
The cuff is depressurized automatically.
If the measured value is in the high blood pressure region, the
values will flash for approximately 5 seconds.
The mark or mark will display after flashing for
5 seconds when movement of the body or irregular pulses were
detected during the measurement. (See pages GB13 and GB14.)
The mark will flash.
The mark is displayed at the pulse rate display area when the
pulse rate could not be measured.
3. To store the measured values, proceed to page GB11.
To complete the measurement, press the Off/On Start button.
* If you forget to switch off the unit it will do so automatically after
approx. 2 minutes.
Date and time is displayed when the display of date and time is
set to ON.
See page GB6 to turn off the display.
Taking a measurement with manual pressurization
Take a measurement with manual pressurization if appropriate pressurization is not
possible after repeated pressurization.
Value 30–40 mmHg higher than
expected systolic blood pressure
1. With the unit turned off, press the Off/On Start
button and hold it to pressurize the cuff to 30–40
mmHg higher value than the expected systolic blood
pressure.
The pressurization value on the display will increase
from 0 mmHg while holding down the Off/On Start
button.
It can be pressurized up to 280 mmHg.
CAUTION:
It may cause temporarily internal bleeding when
pressurized more than necessary.
2. Release the Off/On Start button.
When an Error Occurs During Measurement
A will appear on the display to indicate that measurement was
unsuccessful and should be performed again.
Before performing another measurement, always press the Off/On Start button to turn off
the unit and make sure to allow a rest period of 4 to 5 minutes before starting again.
Advice:
In general, blood pressure measurements are lower for the second measurement
because you are less nervous and are more tranquil.
For people who easily get tense, measuring twice each time is very effective.
It is recommended to store all values when performing two measurements or more.
When taking two measurements, always stay quiet for 4 to 5 minutes after the first
measurement before taking the second measurement.