Registration of input signal data
The data of 96 input signals can be registered.
The signals supporting the installed input module are input and their data registered.
The memories are numbered over 12 pages (A to L: 8 data items can be registered on each page),
and the data is registered in the unused memory with the lowest number. If all the memories are used,
the data of the old signals is overwritten in sequence.
The names of the registered data are automatically determined by the input signals and memory
numbers.
The input signal data must be registered because it is not registered on shipment of the projector.
Note
Renaming the registered signals
Registration of new data
When a new signal is supplied, press the MENU button on the remote control or operating section of the main
unit. When its data has been registered, the MAIN MENU screen is displayed.
Press the MENU button.
The MAIN MENU screen will be displayed.
Select SIGNAL LIST with the and
buttons.
Note
MAIN MENU
PICTURE
POSITION
ADVANCED MENU
LANGUAGE
OPTION
TEST PATTERN
SIGNAL LIST
SECURITY
:MENU SELECT
ENTER:SUB MENU
REGISTERED SIGNAL LIST
A1:SVGA72-A1 RGB1
A2:SVGA72-A2 RGB1
A3:SVGA72-A3 RGB1
A4:SVGA72-A4 RGB1
A5:SVGA72-A5 RGB1
A6:SVGA72-A6 RGB1
A7:SVGA72-A7 RGB1
A8:SVGA72-A8 RGB1
:SELECT ENTER:DETAILS STD:DELETE
REGISTERED SIGNAL STATUS
NAME: SVGA72-A2
MEMORY NO: A2
S.S.NO:
INPUT NO: RGB1
fH: 48.08kHz
fV: 72.17Hz
SYNC. STATE: H(POS)
V(POS)
ENTER:CHANGE NANE
Press the ENTER button.
The REGISTERED SIGNAL LIST screen will be
displayed. The memories extend over 12 pages (A
to L with 8 data items each, giving a total of 96
memories).
Select the signal whose details are to
be displayed with the
, ,
and
buttons.
Press the ENTER button.
The REGISTERED SIGNAL STATUS screen will
be displayed.
The data items including the input signal
name, memory number, signal selector
input number, input terminal, frequency
and sync signal are automatically
identified and displayed.
When the MENU button is pressed, the
REGISTERED SIGNAL LIST screen is
restored.