INSTALLATION
1. Disassembling the Camera
(1) Loosen the fixing screw to separate the
camera mounting base and the camera.
Push up the screwdriver once before
removing the screw.
(2) Turn the camera mounting base approx-
imately 15 degrees counterclockwise
and remove the base from the camera.
2. Setting the Switches
There are two DIP switches on the camera:
an 8-bit switch and a 4-bit switch. The 8-bit
DIP switch is used in both ways to return to
the factory default settings and to specify the
unit number. The 4-bit DIP switch selects ter-
mination ON/OFF and half/full duplex selec-
tion for RS485 communications. Switch set-
tings are read in to the camera when the
power is turned on. Make sure to turn it off,
then turn it back on after changing the
switch settings. Switch positions and func-
tions are shown below.
RS485 Parameter Setup
The selected protocol, communication para-
meters, and set unit numbers are read into
the camera when power is switched on.
1. Switch off the camera.
2. Set the switch according to the function
shown in the table.
3. Switch on the camera to read in the
changed switch settings.
4. Switch off the camera.
5. Set the unit number with the DIP switch
(see next page).
6. Switch on the camera to read in the
changed switch settings.
Note: The changed communication
parameters are displayed on the
RS485 SETUP menu after the cam-
era has been switched on.