REMOTE Specifications (continued)
g Assignment of item priority levels
When both “MARKER1” and “MARKER2” are ON at the same time, “MARKER1” has priority. However, when the
display aspect is 4:3, the “MARKER1” aspect is 16:9, and the “MARKER2” aspect is 4:3, “MARKER2” is
displayed. In this case, the “MARKER2” background is controlled.
When “MARKER BACK HALF” and “MARKER BACK BLACK” are simultaneously activated, priority goes to
“MARKER BACK BLACK”.
When two or more of the following items - “INPUT SEL. VIDEO”, “INPUT SEL. Y/C”, “INPUT SEL SDI1”, “INPUT
SEL. SDI2” and “INPUT SEL. YP
BPR/RGB” - are simultaneously activated, priority goes to the last item activated.
When “GAMMA SEL. FILM” and “GAMMA SEL. STDIO/PST” are simultaneously activated, priority goes to
“GAMMA SEL. FILM”.
Refer to the following diagram and lower right table for the RS-232C terminal pin arrangement and connections.
Please contact the vendor for information about detailed systems which used the RS-232C.
g Connectors and signal names
Connector: D-SUB 9-pin (female)
Signal name
g Communication Conditions
g Command format
Commands are 3 characters following STX, finally
adding ETX.
Add a : (colon) after the command as required, and
add the data.
g Response formats
1. Setting command response
2. Query command response
3. Error response
Error code
ER001: Invalid command
ER002: Parameter error
RS-232C terminal
PC Side (Straight) BT-LH2600W Side
Pin number Signal Pin number Signal
1N.C. 1N.C.
2 RXD 2 TXD
RS-232C Terminal (9P) 3 TXD 3 RXD
4DTR 4DSR
5GND 5GND
6DSR 6DTR
7RTS 7CTS
8 CTS 8 RTS
9N.C. 9N.C.
RS-232C REMOTE operation method
Pin
number
Signal
name
Explanation
1 N.C. Not connected
2 TXD Transmission data
3 RXD Reception data
4 DSR Connected inside.
5 GND Ground
6 DTR Connected inside.
7 CTS Connected inside.
8 RTS Connected inside.
9 N.C. Not connected
Signal level Conforms to RS-232C
Synchro system Tone pace synchro system
Transfer rate 9600 bps
Parity None
Data length 8 bit
Stop bit 1 bit
Flow control None
STX (02h) Command : Data ETX (03h)
STX (02h) Command ETX (03h)
STX (02h) Data ETX (03h)
STX (02h) Error code ETX (03h)