Normalization
When both main unit buttons and remote control are disabled due to the “Button lock”, “Remocon User level” or “Remote
ID” adjustments, set all the values “Off” so that all the buttons are enabled again.
Press the button on main unit together with button on the remote control and hold for more than 5 seconds.
The “SHIPPING” menu is displayed and the lock is released when it disappears.
2/3
Options
Off
Off
Off
Off
0
Remote ID
Serial ID
ID select
Button lock
Remocon User level
Item Effect Adjustments
Button lock
Off MENU&ENTER On
Off: All the buttons at the bottom of the main unit can be used.
MENU & ENTER:
Locks
MENU
and
ENTER/
buttons on bottom face of main unit.
On: Locks all the button on bottom face of main unit.
Remocon
User level
Off User1 User2 User3
Off: You can use all of the buttons on the remote control.
User1:
You can only use , , , , , , , buttons on the remote
control.
User2:
You can only use
, , buttons on the remote control.
User3:
Locks all the buttons on remote control.
ID select
Sets panel ID number when panel is used in “Remote ID” or “Serial ID”.
Set value range: 0 - 100
(Standard value: 0)
Remote ID
Off On
Off: Disables ID remote control functions. You can use normal remote control operations.
On: Enable ID remote control functions.
Serial ID
Off On
Sets the panel ID Control.
Off: Disables external control by the ID.
On: Enables the external control by the ID.
Item Effect Adjustments
Slot Power
Off Auto On
Off: Power is not transmitted to the slot power.
Auto: Power is transmitted to the slot power only when main power is on.
On: Power is transmitted to the slot power when main power is on or in the standby state.
Note: In some cases, power is transmitted to the slot power when main power is on or in the
standby state regardless of the slot power setting.
V.Installation
Off On
Off: Sets fan to the horizontal installation mode.
On: Sets fan to the vertical installation mode.
Notes:
• This functions when display is turned on.
Turn up the power switch for the upward direction when you set Display vertically.
Rotate
Off On
Off: Does not rotate the image.
On: Rotates the image 180 degrees.
Serial Slot
Select
Slot1 Slot2 Slot3
Selects the slot which communicates serial.
Note:
The setting of an external command can be set only from the xed serial terminal (see page 10).
3/3
Options
Off
Off
Off
V. lnstallation
Rotate
Slot1
Serial Slot Select
Slot power