Menu Default Setting Setting Options / Display
T for heating ON
5 °C
Set T for heating
ON.
Outdoor temp. for heater ON
0 °C
Temperature for
heater ON
6.2
*
1,
*
2
Cool
To set various water & ambient
temperatures for cooling.
Water temperatures for cooling ON
and
T for cooling ON.
Water temp. for cooling ON
Compensation curve
Cooling ON
temperatures in
compensation curve or
direct input.
Water temp. for cooling ON Compensation curve
X axis: 20 °C, 30 °C
Y axis: 15 °C, 10 °C
Input the 4 temperature
points
(2 on horizontal X axis,
2 on vertical Y axis)
If 2 zone system is selected, the 4 temperature points must also be input for Zone 2.
“Zone 1” and “Zone 2” will not appear on the display if only 1 zone system.
Water temp. for cooling ON Direct
10 °C
Set temperature for
Cooling ON
T for cooling ON
5 °C Set
T for cooling ON
Menus
For installer
*1
The system is locked to operate without COOL mode. It can be unlocked only by authorised installers or our authorised service partners.