Page view 22
1kW 1kW1kW
4,0
kW
* SCOP On heating mode, XE/E9-NKE compared with electrical heaters at +7°C
Economical, environment-friendly operation
high SCOP (Seasonal Coefficiency of
Performance)
Original Panasonic Inverter technology and a high-performance compressor
provide top-class operating efficiency. This lets you enjoy lower electricity
bills while contributing to environmental protection.
* SCOP On heating mode for VE9-NKE compared with electrical heaters at +7°C
1kW 1kW1kW
5,40
kW
Seasonal Efficiency: New Energy Efficiency Label
From January 2013, the energy performance calculation for air conditioning systems will
change from an overall EU based standard of EER and COP to a new standard based seasonal
efficiencies of SEER and SCOP. These changes to the Energy Related Products Directive or
ErP are designed to give consumers a better understanding of the real efficiency of air
conditioning and heat pump systems whose nominal power rating does not exceed 12 Kw.
Undergoing gradual implementation from 1 January 2013 until 1 January 2019, the schedule
for each product category is as follows:
01 January 2013: A+++, A++, A+, A, B, C, D, E, F and G.
01 January 2015: A+++, A++, A+, A, B, C, D, E and F.
01 January 2017: A+++, A++, A+, A, B, C, D and E.
01 January 2019: A+++, A++, A+, A, B, C and D.
Seasonal Energy Efficiency Ratio (SEER) – This is the overall energy efficiency ratio of the
unit, representative of the entire cooling season. It is calculated as the annual cooling
demand divided by the annual consumption of electricity for cooling.
Seasonal Coefficient of Performance (SCOP) - This is the overall coefficient of performance
of the unit, representative of the entire heating season designated (the value of SCOP
corresponds to a determined heating season). It is calculated by dividing the reference
annual heating demand by the annual consumption of electricity for heating.
SEER > 7.00 SCOP > 5.10
6.10 · SEER < 7.00 4.60 · SCOP < 5.10
5,60 · SEER < 6.10 4.00 · SCOP < 4.60
5.10 · SEER < 5.60 3.40 · SCOP < 4.00
4.60 · SEER < 5.10 3.10 · SCOP < 3.40
4.10 · SEER < 4.60 2.80 · SCOP < 3.10
3.60 · SEER < 4.10 2.50 · SCOP < 2.80
3.10 · SEER < 3.60 2.20 · SCOP < 2.50
2.60 · SEER < 3.10 1.90 · SCOP < 2.20
SEER · 2.60 SCOP · 1.90
CS-***
· Supplier’s name or trademark
· Supplier’s model identifier
· SEER and SCOP indication
· A-G scale
· Energy efficiency class(es)
· Rated capacity for cooling and
heating in kW
SCOP and SEER values, rounded
up to one decimal
Annual energy consumption in
kWh/annum
· Noise emissions
· European map and colour
squares
· Reference period
4.3 A+
SCOP
SEASONAL COEFFICIENT
OF PERFORMANCE
5.4 A+++
SCOP
SEASONAL COEFFICIENT
OF PERFORMANCE
6.7 A++
SEER
SEASONAL ENERGY
EFFICIENCY RATIO
8.6 A+++
SEER
SEASONAL ENERGY
EFFICIENCY RATIO
A
+
SCOP
A
+++
SCOP
SEASONAL
EFFICIENCY
PRODUCT FOLLOWS THE NEW
ECODESIGN REQUIREMENTS
23
DOMESTIC
Page view 22