Page view 14
Note:
R Re
fer to the documentation of the compatible
room monitor for wiring schematics.
R Refer to “Wire and cable specifications”,
Page 17 for information on the type and length
of wires that can be used.
Information about the vandal proof
fe
ature
When the door station is installed using the
mounting base, the mounting base presses
against the vandal proof button and holds the
button down as long at the door station is attached
to the mounting base. If there is an attempt to
remove the door station from the mounting base,
the vandal proof button is released and the vandal
proof feature sounds an alert for 3 minutes.
Note:
R If this alert is triggered accidentally during
installation, or to avoid false detections when
performing maintenance, disconnect the door
station from the power supply by disconnecting
the DC plug or by cutting the power to the
power supply unit.
R To avoid false detections during installation, the
vandal proof feature cannot be triggered unless
the vandal proof button has been pressed down
continuously for 3 minutes.
Installing the relay box (sold
se
parately)
A relay box must be used when connecting an
electric lock to the door station.
Required items
R
elay box (VL-RLY1; sold separately)
Cable binders (included with relay box)
Screws (included with relay box)
Electric lock (user supplied)
Wires connections (user supplied)
See “Wire and cable specifications”, Page 17
for specifications.
Connecting the wires
1 St
rip the ends of the wires that connect to the
relay box as shown below.
Door station wires Electric lock wires
9 mm
25 mm
7 mm
2 R
emove the cable cover screw and then
r
emove the cable cover.
R1 R2 R3
1 2
A
B
A Screw
B Cable cover