Using Web Browser Control
Contents of mail sent
Mail with the contents shown below is sent when the E-mail
settings have been established.
Adjust clock page
Click [Network set up], then [Adjust clock] to display the Adjust clock page.
Mail with the contents shown below is sent
when an error has occurred.
Subject: Panasonic projector report(CONFIGURE)
=== Panasonic projector report(CONFIGURE) ===
Projector Type : D3500
––––– E-mail setup data –––––
TEMPERATURE WARNING SETUP
MINIMUM TIME at [ 60] minutes interval
INPUT AIR TEMPERATURE Over [ 45C / 113F ]
ERROR [ ON ]
LAMP RUNTIME [ OFF ] at REMAIN [ 0] H
LAMP RUNTIME [ OFF ] at REMAIN [ 0] H
INPUT AIR TEMPERATURE [ OFF ]
PERIODIC REPORT
Sunday [ OFF ] Monday [ OFF ] Tuesday [ OFF ] Wednesday [ OFF ]
Thursday [ OFF ] Friday [ OFF ] Saturday [ OFF ]
00:00 [ OFF ] 01:00 [ OFF ] 02:00 [ OFF ] 03:00 [ OFF ]
04:00 [ OFF ] 05:00 [ OFF ] 06:00 [ OFF ] 07:00 [ OFF ]
08:00 [ OFF ] 09:00 [ OFF ] 10:00 [ OFF ] 11:00 [ OFF ]
12:00 [ OFF ] 13:00 [ OFF ] 14:00 [ OFF ] 15:00 [ OFF ]
16:00 [ OFF ] 17:00 [ OFF ] 18:00 [ OFF ] 19:00 [ OFF ]
20:00 [ OFF ] 21:00 [ OFF ] 22:00 [ OFF ] 23:00 [ OFF ]
––––– check system –––––
MAIN CPU BUS [ OK ]
FAN [ OK ]
OPTICS MODULE TEMPERATURE [ OK ]
INPUT AIR TEMPERATURE [ OK ]
AROUND LAMP TEMPERATURE [ OK ]
LAMP REMAIN TIME [ OK ]
Subject: Panasonic projector report(ERROR)
=== Panasonic projector report(ERROR) ===
Projector Type : D3500
––––– check system –––––
MAIN CPU BUS [ OK ]
FAN [ OK ]
OPTICS MODULE TEMPERATURE [ OK ]
INPUT AIR TEMPERATURE [ OK ]
AROUND LAMP TEMPERATURE [ OK ]
LAMP REMAIN TIME [ OK ]
LAMP STATUS [ FAILED ]
SHUTTER [ OK ]
OPTICS MODULE TEMP.SENSOR [ OK ]
INPUT AIR TEMP.SENSOR [ OK ]
AROUND LAMP TEMP.SENSOR [ OK ]
BATTERY [ OK ]
COLOR WHEEL [ OK ]
(Error code 00 40 00 00 00 00 00 00)
Input air temperature : 27 degC / 80 degF
Optics module temperature : 65 degC /149 degF
Around lamp temperature : 27 degC / 80 degF
SET RUNTIME 1857 H
POWER ON 248 times
LAMP ON 177 times
LAMP LOW 0 H
LAMP HIGH 68 H
LAMP REMAIN 1432 H
––––– Network configuration –––––
IP address 192.168.0.8
MAC address 00:00:00:00:00:00
Wed Jan 26 18:54:31 2005
––––– Memo –––––
Time zone selection
Button to update time zone
setting
Button to update time and
date settings
New date field
New time field
If the time becomes incorrect immediately after setting the correct time, then the battery needs to
be changed. Contact the dealer where you bought the projector to have the battery changed.
Note