[Age and gender judgment]
Register the areas to perform face matching / age
and gender judgment. The result of the face detection
that is performed in this area will be targeted for the
face matching and the statistical processing accord-
ing to ages and genders. The settings are the same
as the area settings for face matching that is per-
formed on [Face registration] of the [Event setup] tab
of the "Basic setup" page - the [REC & event] tab. (
NV200K Operating Instructions)
Step 1
Click the [Fix area >] button of "Face matching / age
and gender judgment" on the business intelligence
setup page ( page 8).
The window for setting up the face matching / age
and gender judgment area will be displayed.
The following are displayed on the image display
area.
Green frame: Face detection (The frame will be
updated every second.)
Aqua frame: People counting area ( page 9)
Step 2
Click the [Fix area] button next to the respective face
matching / age and gender judgment area. A maxi-
mum of 4 areas can be registered to allow for polygo-
nal shapes.
Note:
• Configurethesettingsothatthepeoplecounting
area is included in the face matching / age and
gender judgment area.
Step 3
On the displayed image, click the upper left and lower
right corner of the square that will become the desig-
nated area.
The designated area will turn gray and will be reg-
istered as a face matching / age and gender judg-
ment area. If even part of the green frame is over-
lapped with the face matching / age and gender
judgment area, the portion within a green frame
will be targeted for the statistical processing.
Step 4
To complete the settings, click the [Back] button.
The screen returns to the business intelligence
setup page.
Note:
• Aseachareawillbesetuptomatchtheimage
display area divided into 16x16 segments, the top
left and bottom right detection areas may not be
exactly as designated.
• Todeletearegisteredarea,clickthe[Deletearea]
button for the area to delete.