44 - Installation Instructions
Checking After Installation
Installation checklist
3
2
4
65
7
1
5 6 5 6
1) Anchor bolts
Have you removed them and attached
the cover caps properly?
2) Location
Is the appliance on a flat, stable
surface?
Does it run without vibrating?
3) Water-supply hose
Is it free from leaks?
Is the water supply normal?
4) Water-drain hose
Is it free from leaks?
Does it drain normally?
5) Adjustable stands
Are they bolted securely to the
appliance?
6) Stand cushions
Are they standing flat?
If the appliance is not level, there may
be abnormal sounds when water is
drained out.
7) Power supply
Is the household dedicated mains
socket, fully rated at AC 220 V to 240 V?
Test run after installation
After the appliance has been completely
installed where it is to be used, run the spin
cycle to check for water leaks, abnormal noises,
and whether the water gets properly drained off.
Perform the following procedures
WITHOUT laundry in the drum.
1. Turn on the tap.
2. Close the door.
3. Press the On button, and then select
the Quick 50 programme.
4. Select the Spin only mode of the Mode
function, using the Option button, and
then press the Start button.
Wait until the water drains out.
5. While holding down the
and
Help buttons, press the On button.
Help
6. When the following numbers are displayed
(3 seconds), press the Help button.
8
:
88
Help
The remaining time is displayed as below.
0
:
03
The test is run for about 3 minutes.
Check the following:
- Is there any abnormal noise?
If so, make sure that the appliance is level.
- Is there any water leakage?
If so, make sure that the hoses are
properly connected.
You may get the following errors:
- (U11) Unable to drain
Are the hoses properly connected?
Is the drain clogged?
- (U14) Unable to supply water
Have you properly connected the water-
supply hose and turned on the tap?
After recovering from an error, reopen and
reclose the door to resume the test.