Panasonic WJHD316 Operations Instructions Page 104

  • Download
  • Add to my manuals
  • Print
  • Page
    / 164
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 103
104
Recording Rate and Image Quality for Each
Camera Channel
Perform the settings for recording rate, image quality and
recording duration for each camera channel (only for event
pre-recording and event post-recording).
Perform the settings for each recording mode. Assign the
recording rate for each camera channel as described in
"Recording Rate for Each Recording Mode" above.
The following are for the recording rate. When OFF is
selected, images from the selected camera channel will not
be recorded.
OFF/0.1 ips/0.2 ips/0.3 ips/0.4 ips/0.5 ips/1 ips/1.7 ips/
2.5 ips/4.2 ips/5 ips/6.3 ips/8.3 ips/12.5 ips/25 ips/50 ips
AUTO: The recording rate will be set automatically. (Not
possible for event pre-recording and event post-record-
ing)
Important:
The total recording rates of each camera channels in
the same recording mode must be less than the record-
ing rate as described in "Recording Rate for Each
Recording Mode" above.
Examples: When selecting "FIELD" for resolution,
"12.5 ips" for manual recording, "12.5 ips" for sched-
ule recording, "25 ips" for event recording:
Total recording rates of CAM 1 - 16 (manual recording):
less than 12.5 ips
Total recording rates of CAM 1 - 16 (schedule record-
ing): less than 12.5 ips
Total recording rates of CAM 1 - 16 (event recording):
less than 25 ips
When the total of the recording rates becomes more than
the set value, the recording mode table will turn red.
The total recording rates between recording rates of event
pre-recording and recording rates of event post-recording
for each camera channel must be less than the recording
rate as described in "Recording Rate for Each Recording
Mode" above.
The following are available for the image quality.
SFA/SFB: Top quality (SUPER FINE)
FQA/FQB: High quality (FINE)
NQA/NQB: Standard quality (NORMAL)
EXA/EXB: Low quality (EXTENDED)
**A is suitable for less dynamic images.
**B is suitable for more dynamic images.
The following are available for the recording duration (only
event pre-recording and event post-recording).
1 s - 10 s (in 1 second intervals)
20 s/30 s/1 - 10 m (in 1 minute intervals)
20 - 60 m (in 10 minutes intervals)
MAN. (MANUAL): The recording duration will be as follows
depending on the event type.
At a motion detection: For 8 seconds
At a video loss occurrence: During a video loss occur-
rence
At a terminal alarm occurrence: During the supply of a
signal
At a command alarm: For 8 seconds
CON. (CONTINUE): Recording will be performed continu-
ously until the ALARM RESET button is pressed.
Notes:
•When performing event pre-recording from a camera
channel that does not have its own event pre-recording
area, recording time of pre-recording will differ depend-
ing on the settings of "Resolution" and "Recording Rate
and Quality" for event pre-recording. When the set
recording time is longer than the maximum possible
recording time, recording rate of pre-recording will be
displayed in red.
•When performing event pre-recording from a camera
channel that has its own event pre-recording area,
recording time of pre-recording will differ depending on
the capacity of recording area, the setting of
"Resolution" and "Recording Rate and Quality" for event
pre-recording. When the set recording time is longer
than the maximum possible recording time, recording
rate of pre-recording will be displayed in red. Refer to
page 134 for further information about pre-recording
area.
Important:
Event pre- recording image only just recorded will be delet-
ed in the following cases:
When the SETUP MENU is closed after changing the
settings
When event post-recording is performed newly
When time zone of a schedule switched and recording
started newly
When date is been changed
Event Shedule
System
Display
Comm
Switcher
SETUP MENU
LIVE
Maintenance Recording
Time Table
REC Prog
Event Prog
Special Days
MON
TUE
WED
THU
FRI
SAT
SUN
EVERY
EXT.
12AM 6AM 12PM 6PM 12AM
REC
:
P1 P2 P3 P4
EVT
:
P1 P2 P3 P4
Resolution
Recording Table
Manual REC
Schedule REC Event REC
FIELD
Recording Program 1
15
ips
ips15 ips30
O K CANCEL
1ips
1ips
1ips
1ips
1ips
1ips
1ips
1ips
1ips
1ips
1ips
1ips
1ips
1ips
1ips
1ips
1ips
1ips
1ips
1ips
1ips
1ips
1ips
1ips
1ips
1ips
1ips
1ips
1ips
1ips
1ips
1ips
SFA
SFA
SFA
SFA
SFA
SFA
SFA
SFA
SFA
SFA
SFA
SFA
SFA
SFA
SFA
SFA
SFA
SFA
SFA
SFA
SFA
SFA
SFA
SFA
SFA
SFA
SFA
SFA
SFA
SFA
SFA
SFA
SFA
SFA
SFA
SFA
SFA
SFA
SFA
SFA
SFA
SFA
SFA
SFA
SFA
SFA
SFA
SFA
SFA
SFA
SFA
SFA
SFA
SFA
SFA
SFA
SFA
SFA
SFA
SFA
SFA
SFA
SFA
SFA
5s
5s
5s
5s
5s
5s
5s
5s
5s
5s
5s
5s
5s
5s
5s
5s
30s
30s
30s
30s
30s
30s
30s
30s
30s
30s
30s
30s
30s
30s
30s
30s
AUTO
AUTO
AUTO
AUTO
AUTO
AUTO
AUTO
AUTO
AUTO
AUTO
AUTO
AUTO
AUTO
AUTO
AUTO
AUTO
1ips
1ips
1ips
1ips
1ips
1ips
1ips
1ips
1ips
1ips
1ips
1ips
1ips
1ips
1ips
1ips
SCHEDULE
TIME TIME
RATE
QUALITY
MANUAL
PRE EVENT POST EVENT
RATE
QUALITY
RATE
QUALITY
RATE
QUALITY
CAM1
CAM2
CAM3
CAM4
CAM5
CAM6
CAM7
CAM8
CAM9
CAM
10
CAM
11
CAM
12
CAM
13
CAM
14
CAM
15
CAM
16
Page view 103
1 2 ... 99 100 101 102 103 104 105 106 107 108 109 ... 163 164

Comments to this Manuals

No comments