● Input/Output Board
q Electric lock connectors
An electric lock is connectable to GATE 1.
Note: GATE 2 is not usable.
Do not connect anything to GATE 2.
w Alarm input/output connectors
(ALARM IN, ALARM OUT)
ALARM IN: These are connectors to input the alarm
signal from the external devices to the control unit.
Alarm-related operations are configurable through
the administration PC. (Refer to the administrator’s
guide of the administration software.)
ALARM OUT: These are connectors to output the alarm
signal from the control unit to the external devices.
Alarm-related parameters are configurable through
the administration PC. (Refer to the administrator’s
guide of the administration software.)
e Iris camera connectors (CAMERA 1 to 3)
These are connectors for communication between iris
cameras and the control unit. Up to 3 iris cameras are
connectable (x 2 for recognition cameras and x 1 for an
enrollment camera).
r Ethernet port (10Base-T/100Base-TX)
This is a port to connect the control unit to LAN (Local
Area Network).
● Power board
q Camera power connectors
These are connectors to supply iris cameras with 32 V
DC power. One connector can supply power to one
camera.
Note: Power supply from one connector to more than
one camera may cause trouble.
w Power input connectors
e Power switch
Turns on/off the power of the control unit. When
pressed, the power is on.
When the power is turned on, the power indicator lights
up and 32 V DC power is supplied from the camera
power connectors to iris cameras.
Note: Do not turn off the power during setting/initializa-
tion.