Panasonic BMED500 Operations Instructions Page 16

  • Download
  • Add to my manuals
  • Print
  • Page
    / 26
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 15
Description and settingOperation mode
Set to this mode when you make iris
cameras enroll people.
Set to this mode when you configure
the control unit's operations via the
administration PC. (Refer to the
administrator’s guide supplied with
the administration software
.)
16
SETTINGS
Description
To use the control unit, the following settings are necessary
with the setting switches or numeric buttons on the setting
board.
Setting/confirmation of the operation mode/IP address
(Operation mode switches)
Electric lock setting (DSW 2)
You will set the existence, type, polarity and unlocking
timer of electric locks.
IP address
You will set if you connect the control unit to the PC via
LAN and control this unit from the PC.
In addition to these settings, you need the configuration
through the administration PC. (Refer to the administrator’s
guide of the administration software.)
Note: When you set the control unit's operations through
the administration PC, you need to change the opera-
tion mode to the SETUP mode.
To Do Setting without the
Buzzer Sound
When you open the door, the buzzer will beep to notify you
that the door is open. Then, the recognition procedures with
iris cameras will be unavailable. If you open the door for
maintenance, etc., do the following procedure.
1. Open the door with the supplied key.
The buzzer will beep and recognition is stopped.
2. Pull the door sensor.
3. Restart the recognition from the administration PC.
You can do setting without the buzzer sound and you
can continue the recognition with iris camera during the
setting. (Setting changes will not be reflected until turn-
ing on the power again.)
4. After the setting, close the door.
The buzzer will beep again.
5. Restart the recognition from the administration PC.
When you open the door again for setting, do steps 1 to
3 again.
Operation Mode Setting
The control unit has four operation modes. They are config-
urable with 1 to 3 of the operation mode switches. (The fac-
tory default setting is shown in the figure.)
Notes:
Change the operation mode after turning off the power
of the control unit. When you change the mode while
power is on, the setting will not be reflected to the con-
trol unit until turning on the power again.
To turn the power off, refer to p.19.
POWER ALARM S3 S2 S1
CN1
1 2 3 4 5
6 7 8 9
RESET
0
#
MIN
+–
BZ1
VR1
MAX
R1
R7
R6
R4
R5
1
1
9
OFF FSK
2 3 4 5 6 7 8
Door sensor
Pull this immediately after
opening the door.
Operation mode switches
(DSW3)
POWER ALARM S3 S2 S1
CN1
IC102
E102E101CN504CN503
CN101
1 2 3 4 5
6 7 8 9
RESET
0
MIN
DSW1
DSW2
+—
BZ1
VR1
MAX
R1
R7
R6
R4
R5
1
1
9
OFF FSK
2 3 4 5 6 7 8
1
1
9
OFF FSK
2 3 4 5 6 7 8
1
9
3
OFF FSK
2 3 4 5 6 7 8
1
OFF
2 3 4 5 6 7 8
Unsettable
(Do not change these positions. Error may occur.)
Operation mode
setting
IP setting mode This is the mode to set/confirm the IP
address/gateway address of the
control unit.
1
1
9
OFF FSK
2 3 4 5 6 7 8
1
1
9
OFF FSK
2 3 4 5 6 7 8
1
1
9
OFF FSK
2 3 4 5 6 7 8
SETUP mode
Recognition
mode
Set to this mode when you make iris
cameras recognize people.
1
1
9
OFF FSK
2 3 4 5 6 7 8
Enrollment mode
Page view 15
1 2 ... 11 12 13 14 15 16 17 18 19 20 21 ... 25 26

Comments to this Manuals

No comments