1 Safety Precautions 3 2 Features 5 3 Functions 6 3.1. REMOTE CONTROL 6 3.2. INDOOR UNIT 7 4 Product Specifications 9 5 Dimensions 10 5.1. Casse
5 Dimensions5.1. Cassette Type10CS-ME7EB1E / CS-ME10EB1E / CS-ME12EB1E / CS-ME14EB1E
11CS-ME7EB1E / CS-ME10EB1E / CS-ME12EB1E / CS-ME14EB1E
5.2. Grille12CS-ME7EB1E / CS-ME10EB1E / CS-ME12EB1E / CS-ME14EB1E
6 Refrigeration Cycle Diagram13CS-ME7EB1E / CS-ME10EB1E / CS-ME12EB1E / CS-ME14EB1E
7 Block DiagramCS-ME7EB1E/ME10EB1E/ME12EB1E/ME14EB1E14CS-ME7EB1E / CS-ME10EB1E / CS-ME12EB1E / CS-ME14EB1E
8 Wiring Diagram15CS-ME7EB1E / CS-ME10EB1E / CS-ME12EB1E / CS-ME14EB1E
9 Electronic Circuit Diagram16CS-ME7EB1E / CS-ME10EB1E / CS-ME12EB1E / CS-ME14EB1ECS-ME7EB1E CS-ME10EB1E CS-ME12EB1E CS-ME14EB1E
17CS-ME7EB1E / CS-ME10EB1E / CS-ME12EB1E / CS-ME14EB1E
10 Operation Details (Functions & Protection)10.1. Simultaneous Operation Control 1. Operation modes which can be selected using the remotecontrol
10.2. Airflow Direction ControlThe following shows how louver operation changes depending on the direction set with the AIR SWING button and other ope
13.1. OPERATION CHARACTERISTICS 40 14 Exploded View & Replacement Parts List 45 14.1. Exploded View 45 14.2. Replacement Parts List 462CS-ME7E
10.3. Indoor Fan Control · The following shows how fan speed changes depending on the setting made with the FAN SPEED button and other operati
21CS-ME7EB1E / CS-ME10EB1E / CS-ME12EB1E / CS-ME14EB1E
10.4. Drain Pump ControlBasic operation · The drain pump starts 50 seconds after the indoor unit starts or the thermostat comes on (i.e., 10 se
10.5. Auto Restart Control · if there is a power failure, operation will automatically be restarted when the power is resumed. It will start wi
10.6. Other Indoor Unit Operation Functions10.6.1. Auto buttonProceed with operation when the air conditioner is stopped.(When the auto button is pres
10.6.2. Drain TestWhen installing the unit and you want the drain pump to operate independently, press the DRAIN TEST switch to operate it forabout 5
10.6.3. Self Diagnosis display10.6.3.1. BreakDown Self Diagnosis Function (Three Digits Alphanumeric Code) · Once abnormality has been detected
10.6.3.2. Error Code27CS-ME7EB1E / CS-ME10EB1E / CS-ME12EB1E / CS-ME14EB1ESymbol Diagnosis Diagnosis methodH11 Indoor / OutdoorabnormalcommunicationTh
28CS-ME7EB1E / CS-ME10EB1E / CS-ME12EB1E / CS-ME14EB1ESymbol Diagnosis Diagnosis methodH30 Outdoor dischargepipe temp. sensorDisconnected discharge se
29CS-ME7EB1E / CS-ME10EB1E / CS-ME12EB1E / CS-ME14EB1ESymbol Diagnosis Diagnosis methodH99 Indoor operating unitfreezingThe restriction on the compres
1 Safety Precautions3CS-ME7EB1E / CS-ME10EB1E / CS-ME12EB1E / CS-ME14EB1E
30CS-ME7EB1E / CS-ME10EB1E / CS-ME12EB1E / CS-ME14EB1ESymbol Diagnosis Diagnosis methodF97 Compressor highdischarge temperatureThis error occurs and o
CS-ME7EB1E / CS-ME10EB1E / CS-ME12EB1E / CS-ME14EB1E3111 Installation Instructions
CS-ME7EB1E / CS-ME10EB1E / CS-ME12EB1E / CS-ME14EB1E32
CS-ME7EB1E / CS-ME10EB1E / CS-ME12EB1E / CS-ME14EB1E33
CS-ME7EB1E / CS-ME10EB1E / CS-ME12EB1E / CS-ME14EB1E34
CS-ME7EB1E / CS-ME10EB1E / CS-ME12EB1E / CS-ME14EB1E35
12 Disassembly of PartsHigh voltages are generated in the electrical parts area by the capacitor, Ensure that the capacitor has discharged sufficientl
8) Detach the air guide and unscrew the screw on the heatexchanger.9) Detach the float switch and unscrew the 3 screws anddisengage the 2 catches on t
3) Loosen the screw on the cover and detach the cover.4) Unscrew the 2 screws on the control section cover and detachall connectors.5) Disengage the c
12.4. Detaching the louver motor3) Loosen the screw on the cover and detach the cover.4) Unscrew the 2 screws on the control section cover and detacht
4CS-ME7EB1E / CS-ME10EB1E / CS-ME12EB1E / CS-ME14EB1E
13 Technical Data13.1. OPERATION CHARACTERISTICS40CS-ME7EB1E / CS-ME10EB1E / CS-ME12EB1E / CS-ME14EB1E
41CS-ME7EB1E / CS-ME10EB1E / CS-ME12EB1E / CS-ME14EB1E
42CS-ME7EB1E / CS-ME10EB1E / CS-ME12EB1E / CS-ME14EB1E
43CS-ME7EB1E / CS-ME10EB1E / CS-ME12EB1E / CS-ME14EB1E
44CS-ME7EB1E / CS-ME10EB1E / CS-ME12EB1E / CS-ME14EB1E
14 Exploded View & Replacement Parts List14.1. Exploded ViewNote:The above exploded view is for the purpose of parts disassembly and replacement.T
14.2. Replacement Parts List<Model: CS-ME7EB1E / CS-ME10EB1E / CS-ME12EB1E / CS-ME14EB1E>Ref.No.Part Name & Description Q´ty Part No. Remark
· Serviceability − − − − Self diagnosis − − − − Test Run at both Cooling and Heating rated frequency · Built-in drain pump − −
3 Functions3.1. REMOTE CONTROL6CS-ME7EB1E / CS-ME10EB1E / CS-ME12EB1E / CS-ME14EB1E
3.2. INDOOR UNIT7CS-ME7EB1E / CS-ME10EB1E / CS-ME12EB1E / CS-ME14EB1E
8CS-ME7EB1E / CS-ME10EB1E / CS-ME12EB1E / CS-ME14EB1E
4 Product SpecificationsModel CS-ME7EB1E CS-ME10EB1E CS-ME12EB1E CS-ME14EB1EItem Cassette TypePower Source Outdoor power (single 230V 50Hz)Air Volume
Comments to this Manuals