58
Add 100
g
of water to the
water tank. Ensure drip tray
is empty.
Make a solution of 16
g
citric
acid and 200
g
of water, add
the solution to the water tank.
Ensure drip tray is empty.
Tap System cleaning once until F1
Drain water program appears in
the display.
Tap System cleaning twice
until F2 SYSTEM CLEANING
program appears in the display.
After the program has paused, empty
the drip tray and ll the water tank with
water (to max level).
Touch Start. Empty
the drip tray after the
program has nished.
Touch Start. The
program will
run for approx.
29 minutes.
Touch Start. The program will run for
approx. 1 minute. Empty the drip tray
after the program has nished.
F1. DRAIN WATER
Water is pumped through the system to clean the pipes. The water is drained into the
drip tray.
F2. SYSTEM CLEANING
The rst stage of this program cleans the system with a citric acid solution. The second
stage runs water through the system to rinse the pipes.
System cleaning programs
Note
1. Only run this program with 100
g
of water in the tank.
2. Do not remove the drip tray during the drain water program.
3. Empty the drip tray and rinse with running water after the program has nished.
Caution
4. If the drain water program is used directly after a steam cooking program,
hot water may be drained into the drip tray.
Note
1. symbol appears in the display when running the DRAIN WATER
and
SYSTEM CLEANING program.
2. If the system cleaning program is not used regularly, the pipe will get blocked
and the steaming performance will be less effective.
3. Do not remove the drip tray during the drain program.
4. Empty the drip tray and rinse with running tap water after the program has
nished.