3 Product Specifications
Unit CS-TE9DKE CU-TE9DKE
Cooling Capacity kW
kcal/h
BTU/h
2.60 (0.60 - 3.00)
2,240 (520 - 2,580)
8,870 (2,050 - 10,200)
Heating Capacity kW
kcal/h
BTU/h
3.60 (0.60 - 5.30)
3,100 (520 - 4,560)
12,300 (2,050 - 18,100)
Moisture Removal l/h
Pint/h
1.5
(3.2)
Power Source Phase
V
Cycle
Single
230/240
50
Airflow Method OUTLET
INTAKE
SIDE VIEW TOP VIEW
Air Volume Indoor Air (Lo) m
3
/min (cfm) Cooling; 5.3 (190)
Heating; 6.2 (220)
Indoor Air (Me) m
3
/min (cfm) Cooling; 7.2 (250)
Heating; 8.4 (290)
Indoor Air (Hi) m
3
/min (cfm) Cooling; 9.2 (320)
Heating; 10.5 (370)
dB (A) Cooling; High 39, Low 26 Cooling; 46
Heating; High 40, Low 27 Heating; 47
Noise Level
Power level dB Cooling; High 50 Cooling; High 59
Heating; High 51 Heating; High 60
Electrical Data Input W Cooling; 580 (120 - 720)
Heating; 845 (115 - 1,360)
Running Current A Cooling; 2.7
Heating; 3.9
EER W/W (kcal/hw), BTU/hw Cooling; 4.48(3.86), 15.3
COP W/W (kcal/hw), BTU/hw Heating; 4.26 (3.67), 14.5
Starting Current A 3.9
Piping Connection Port
(Flare piping)
inch
inch
G ; Half Union 3/8”
L ; Half Union 1/4”
G ; 3-way valve 3/8”
L ; 2-way valve 1/4”
Pipe Size
(Flare piping)
inch
inch
G (gas side) ; 3/8”
L (liquid side) ; 1/4”
G (gas side) ; 3/8”
L (liquid side) ; 1/4”
6