Basic Operation
Remote control operation
24 - ENGLISH
You can display the image brightness and
contrast level of the input signal with a
waveform. See “WAVEFORM MONITOR”
on page 32.
J Displaying the waveform
1. Press the WAVEFORM button and display the
waveform monitor.
Press the WAVEFORM button again to escape from
the waveform mode.
2. Press ENTER button until the required waveform
option is displayed.
In FULL SCAN mode, press F G I H to change
the waveform position.
In SINGLE LINE SCAN mode, press F G to select
the required line position.
J Adjustment example
Project a commercial test signal for picture
adjustment on the screen and press the
WAVEFORM button.
Q Adjusting with luminance options
1. Press the ENTER button until FULL SCAN(Y)/
SINGLE LINE SCAN(Y) is displayed.
2. Press the PIC. ADJUST to display the PICTURE
MODE of the PICTURE menu.
3. Press G several times to display the
BRIGHTNESS.
4. Adjust the BRIGHTNESS by pressing I H.
Adjust the bottom line of the waveform to 0%
(0 or 7.5 IRE).
Setting range: -32 to +32
5. Press G once to display the CONTRAST.
6. Adjust the CONTRAST by pressing I H.
Adjust the bottom line of the waveform to 100%
(100 IRE).
Setting range: -64 to +64
Adjusting the signal condition with a waveform
FULL SCAN
Monitoring the waveform of
brightness and contrast of the whole
image.
SINGLE LINE SCAN
Monitoring the waveform of
brightness and contrast in each
horizontal line of the image.
100%
50%
0%
100%
5
0
%
0%
100%
5
0
%
0%
ENTER
ENTER
Optimal
dynamic range
Adjust to 100%
Adjust to 0%
Monitor position
Optimal
dynamic range
Adjust to 100%
Adjust to 0%
Monitor position
COMPUTER (except 1080)
HDMI (Expand)
Signal level
Signal level
FULL SCAN(Y) SINGLE LINE SCAN(B)
FULL SCAN(R) SINGLE LINE SCAN(G)
FULL SCAN(G) SINGLE LINE SCAN(R)
FULL SCAN(B) SINGLE LINE SCAN(Y)
NOTE:
•In SINGLE LINE SCAN mode, the position of the
waveform monitor depends on the position of the
selected line.
You can display the main menu by pressing the MENU
button and adjust the menu items.
The called up menu items displayed position depends
on the position of the waveform monitor.
You can activate AUTO ADJUST of the WAVEFORM
menu by pressing the DEFAULT button.
The signal which is lower than 0% in the waveform will
be displayed as same as 0% on the projected image.
While the waveform is displayed, the image is
displayed without the COLOUR MANAGEMENT
adjustment.
When adjusting the KEYSTONE of the POSITION
menu while the waveform is displayed, xvYCC will be
deactivated.
FULL SCAN(Y)/SINGLE LINE SCAN(Y)
BRIGHTNESS
Adjust the bottom line of the
waveform to 0% (0 IRE or 7.5 IRE)
CONTRAST
Adjust the top line of the waveform
to 100% (100 IRE)