Panasonic WJ-HD100 User Manual Page 13

  • Download
  • Add to my manuals
  • Print
  • Page
    / 60
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 12
13
87654321
REMOTE/ALARM IN
CONTROL IN
ALARM OUT
RECOVER OUT
RESET IN
GGGGGGGGGGG
+24V
NC
NO
To Alarm
Indicator
External device
NC: Normally Closed
NO: Normally Open
Relay
ALARM
G
RECALL
OUT
RECOVER OUT
RESET IN
IN
Digital Disk Recorder
WJ-HD100
Alarm Terminal Connection
A connection example is shown below.
IN: Stands for Alarm Signal In. Connect directly with a
sensor unit or indirectly with a unit having sensor
output capability to the recorder. The recorder
enters alarm recording mode when the alarm signal
(active when low) comes in.
RESET IN: Receives the reset signal (active when low)
from a connected device.
RECOVER OUT: Supplies the reset signal when the
RESET IN is received, the [ STOP] button is
pressed, or the AUTO RESET time elapses.
OUT: Stands for the status output active until an alarm
is reset.
RECALL: The alarm history is displayed on the Monitor
every time the external switch is turned on.
GND: Signal ground
RS-232C Connection
Use an RS-232C cable (not included) as shown below to
connect the RS-232C terminal with a personal computer or
the like. The protocol selection in the COMMUNICATION
SETUP must be set to VCR.
9-pin D-sub connector
(female)
9-pin D-sub connector
(female)
1
2
3
4
5
6
7
8
Frame
1
2
3
4
5
6
7
8
Frame
Shield
PS
Data Connection
Connect the DATA terminal on the rear panel to a system
component with a modular cable (not included) in the PS
Data chain. The protocol selection in the COMMUNICA-
TION SETUP must be set to PS
DATA. Follow the proce-
dure for unit address setup (page 14, 30) and termination
(page 14).
Panasonic part # WV-CA48 series, RS-485 cables and con-
nectors are recommended for the connection.
TB
TA
RB
RA
RX
TX
GND
GND
DATA
TA
TB
RA
RB
TX
RX
Page view 12