27
ALARM SETUP
The digital disk recorder accepts an alarm signal supplied
from connected device such as a camera or camera site
equipment. The recorder also generates an alarm signal
itself when the preset motion detection activates.
Any alarm signal starts alarm recording with the preset
recording mode, field rate and picture quality. Alarm
recording stops when the preset time has elapsed, the [
STOP] [SETUP/ESC] button on the front panel is pressed,
or the alarm RESET IN is supplied from the connected
device. The recorder outputs an alarm recovery signal
from the rear panel.
Alarm Recording Mode
301 REC MODE
This item specifies the recording mode to be applied exclu-
sively to the sequence after an alarm input. The setting
procedure and parameters are the same as for REC SETUP
described earlier.
DURATION 10S
ALARM BUZZER ON
VMD SETUP OFF
Alarm Recording Duration
304 DURATION
This setting specifies the duration of alarm recording and
related functions after an alarm input. Functions active dur-
ing alarm recording are buzzer beeping, ALARM LED indi-
cation, "ALARM" status display, and the ALARM OUT sig-
nal.
1. Move the cursor to DURATION with the [] or [] but-
ton.
2. Select the desired duration with the JogDial.
The default value is 10 seconds.
The unit will revert to the previous status when the time
has elapsed.
10S: 10 seconds
20S: 20 seconds
30S: 30 seconds
1M: 1 minute
2M: 2 minutes
3M: 3 minutes
6M: 6 minutes
MANUAL: Recording continues for as long as there is
alarm input or for at least 10 seconds, even if the
alarm input turns off earlier.
CONTINUE: Recording continues until the stop button
on the front panel is pressed, or the RESET IN sig-
nal is supplied.
OFF: Neither recording nor alarm logging is implement-
ed.
Alarm Buzzer
305 ALARM BUZZER
DISPLAY SELECT
LCD CONTRAST
DISPLAY SELECT
LCD CONTRAST
1. Move the cursor to ALARM BUZZER with the up [] or
down [] button.
ALARM SETUP
REC MODE SF- 12H
REC RATE 15FPS
REC QUALITY 10(1-10)
DURATION 10S
ALARM BUZZER ON
VMD SETUP OFF
REC MODE SF- 12H
REC RATE 15FPS
REC QUALITY 10(1-10)
DISPLAY SELECT
LCD CONTRAST
ALARM SETUP
REC MODE SF- 12H
REC RATE 15FPS
REC QUALITY 10(1-10)
DURATION 10S
ALARM BUZZER ON
VMD SETUP OFF
Page view 26