Reset Pulse Polarity
106 RESET PULSE
The polarity of the alarm reset pulse is selected in the
SYSTEM SETUP window.
The reset pulse is supplied from an external device with
high or low active signal form to the RESET IN terminal
on the rear panel.
1. Open the system setup window, then move the cursor
to RESET PULSE with the up [] or down [] button.
2. Select either HIGH or LOW with the JogDial. The default
is HIGH.
HIGH: Stands for high-active. The recorder stops alarm
recording when a positive pulse is supplied.
LOW: Stands for low-active.
Time Adjusting
107 TIME ADJUSTING
IN and OUT terminals for a calibration signal are provided
on the TIME ADJUST terminal board on the rear panel. The
master unit supplies the calibration signal to the slaves.
This is convenient for synchronizing the internal clock with
other connected devices. Make certain to connect the IN
and OUT terminals correctly.
1. Move the cursor to TIME ADJUSTING with the [] or
[] button.
2. Select either MASTER or SLAVE with the JogDial. The
default is SLAVE.
MASTER: The unit supplies the calibration OUT signal
to the slave units.
SLAVE: The internal timer of the unit is supplied the cali-
bration signal from the master.
1. Move the cursor to AUTO ERASING with the [] or []
button.
2. Select the desired day number with the JogDial.
OFF: Auto erasing is not applied.
1DAY: Only todays records of 0:00 onward are protect-
ed. Records before 24:00 of yesterday are erased.
2 to 10DAYS: Records before the specified number of
days are erased.
14, 30, 45, 60, 90, 120, 150, 180DAYS: Same as
above.
Notes:
The day number includes today as 1 day, therefore
2DAYS counts today and yesterday in number.
Auto Erasing is implemented at 24:00 mid night.
Playing back will stop once when the time comes to
24:00, then will restart with different portion based
on the renewed day count.
SYSTEM SETUP
FWD/REW MODE SKIP&PLAY
PASSWORD LOCK OFF
ALL
*****
OPERATION
*****
KEYLOCK BUZZER OFF
RESET PULSE HIGH
TIME ADJUSTING SLAVE
SET TIME
9:00
AUTO ERASING OFF
Set Time
108 SET TIME
This setting specifies the hour for the master unit to supply
the Time Adjust OUT signal to the slave units once a day.
You need not set the hour when SLAVE is selected. The
slave unit accepts the signal through the IN terminal, and
corrects its internal clock to the hour as far as the clock
deviates within 15 minutes after or before the hour.
1. Move the cursor to SET TIME with the [] or [] button.
2. Select the desired time (00:00 to 23:00) with the
JogDial.
3. Press the JogDial.
Auto Erasing
109 AUTO ERASING
The redundant records on the disk can be erased every
day at 24:00 mid night. Day numbers specified by this set-
ting means that the records stored during the number of
days from the present will be protected, while the older
records than that of the protected day will be erased.
SYSTEM SETUP
FWD/REW MODE SKIP&PLAY
PASSWORD LOCK OFF
ALL
*****
OPERATION
*****
KEYLOCK BUZZER OFF
RESET PULSE HIGH
TIME ADJUSTING SLAVE
SET TIME
9:00
AUTO ERASING OFF
SYSTEM SETUP
FWD/REW MODE SKIP&PLAY
PASSWORD LOCK OFF
ALL
*****
OPERATION
*****
KEYLOCK BUZZER OFF
RESET PULSE HIGH
TIME ADJUSTING SLAVE
SET TIME
9:00
AUTO ERASING OFF
Page view 22
1 2 ... 18 19 20 21 22 23 24 25 26 27 28 ... 59 60

Comments to this Manuals

No comments