Appendix
PJLink protocol
The network function of the projector supports PJLink class 1, and the PJLink protocol can be used to perform
projector setting and projector status query operations from a computer.
Control commands
J
The following table lists the PJLink protocol commands that can be used to control the projector.
Command Control details Notes
POWR Power supply control
Parameters
0 = Standby
1 = Power ON
POWR ? Power supply status query
Parameters
0 = Standby 1 = Power ON
2 = Cool-down in progress 3 =Warm-up in progress
INPT Input selection Parameters
11 = Computer 1 12 = Computer 2
21 = VIDEO 22 = S-VIDEO 31 = HDMI
INPT ? Input selection query
AVMT AV MUTE control Parameters
30 = AV MUTE mode off
31 = AV MUTE mode on
AVMT ? AV MUTE status query
ERST ? Error status query
Parameters
1st byte : Indicates fan errors, range 0 – 2
2nd byte : Indicates lamp errors, range 0 – 2
3rd byte : Indicates temperature errors, range 0 – 2
4th byte : Fixed at 0
5th byte : Indicates lter errors, range 0 – 2
6th byte : Indicates other errors, range 0 – 2
Denitions for each value from 0 to 2 are as follows.
0 = No error known 1 = Warning 2 = Error
LAMP ?
Lamp status query
Parameters
1st digits (1 – 5 digits) : Lamp cumulative operating time
2nd digit : 0 = Lamp off, 1 = Lamp on
INST ?
Input selection list query
The followings are returned as parameters.
“11, 12, 21, 22, 31”
NAME ? Projector name query The name set for [Projector name] in [LAN Settings] is returned.
INF1 ? Manufacturer name query “Panasonic” is returned.
INF2 ? Model name query Answer the model name with "CW330E", "CW240E" or "CX300E".
CLSS ? Class information query 1” is returned.
PJLink security authorization
J
The password for PJLink is the same as the password for Web Management.
(Æpage 52)
When using PJLink without security authorization, set use without the password in Web Management.
For specications regarding PJLink, refer to the Japan Business Machine and Information System
Industries Association website.
http://pjlink.jbmia.or.jp/english/