Panasonic MINAS A4P Series User Manual Page 97

  • Download
  • Add to my manuals
  • Print
  • Page
    / 232
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 96
97
[Setting]
Setting
Starting from the initial LED status, press four time after pressing ,
then brings the display of normal
auto-gain tuning,
then press
to select the machine 
stiffness No.
When you have finished the tuning, press to return to .
<Remarks>
Don't disconnect the console from the driver between and .
Should the connector is pulled out, insert it again and repeat the procedures from the beginning.
<Note> If the following status occurs during the tuning action, the tuning error occurs.
(1) During the tuning action, 1) when an error occurs, 2) when turned to Servo-OFF, 
3) even the deviation counter is cleared and 4) when the tuning is actuated close to the limit switch.
(2) When the output torque is saturated because the inertia or load is too large.
(3) When the tuning can not be executed well causing oscillation.
If the tuning error occurs, value of each gain returns to the previous value before the tuning. The
driver does not trip except error occurrence. Depending on the load, the driver might oscillate without
becoming tuning error. (not showing ) Extra attention should be paid to secure the safety.
Starting of the motor
Tuning finishes.
Tuning errorTuning completes
machine stiffness No.
(1 to 9, A (10) to F (15))
<Note>
For machine 
stiffness No., 
refer to P.148.
<Note>
To prevent the loss of
gain value due to the
power shutdown, write
into EEPROM.
Press to make 
EXECUTION DISPLAY to
After inhibiting command input, and during Servo-On status,keep pressing until 
Console (LED) display changes to .
“ ” increases by pressing (approx. 5sec) 
as the left fig. shows.
SELECTION display
Auto-Gain Tuning Mode
Normal Mode Auto-Gain Tuning Screen
<Remarks>
•For details of normal auto-gain tuning, refer to P.148, "Normal Auto-Gain Tuning" of Adjustment. Pay a
special attention to applicable range and cautions.
The motor will be driven in a preset pattern by the driver in normal auto-gain tuning mode. You can change
this pattern with SV.Pr25 (Normal auto tuning motion setup), however, shift the load to where the operation
in this pattern may not cause any trouble, then execute this tuning.
Depending on the load, oscillation may occur after the tuning. In order to secure the safety, use the
protective functions of SV.Pr26 (Software limit set up), SV.Pr70 (Position deviation error level) or SV.Pr73
(Overspeed level).
Operation at SELECTION display
Operation at EXECUTION display
Page view 96
1 2 ... 92 93 94 95 96 97 98 99 100 101 102 ... 231 232

Comments to this Manuals