Setup with the Front Panel
Composition of Touch Panel and Display
Display LED (2 digits)
In the case of an error, the alarm code will flash.
In the case of a warning, the warning code (about 2 seconds)
will alternate at about 4 seconds intervals with .
ID address setup rotary switch
LSD : Lower-shifting (Default : 0)
MSD : Upper-shifting (Default : 0)
For manufacturers' use only. 
(Not for individual use)
Output signal (Analog signal)
Speed monitor output
Torque monitor output
Signal ground
Initial Status of the Front Panel Display (7-Segment LED)
When an alarm has been given, an alarm code of two-digit decimal number blinks on the front panel display
(7-segment LED) of this servo driver. When no alarm is given, the display shows as follows:
After approximately 2 seconds
All the segments turn on
(Light check)
Baud Rate indicated
ID address indicated
Hyphens indicated
An alarm code blinks.
(In the case of overflow)
• When an alarm has been given
A dot blinks 
(at the right-hand side)
Normal display
(Alarm code 0)
After approximately 0.5 seconds
(A set value)
(A set value)
Control power supply
turns on
After approximately 0.5 seconds
After approximately 0.5 seconds
After approximately 0.5 seconds
Main power supply
turns off
SERVO READY = 0
Main power supply
turns on
SERVO READY = 1
“Servo off” command
“Servo on” command
“Servo off”
command
“Servo on”
command
A warning code and normal state are shown in turn
Warning code
(Approximately 2 seconds)
Normal display
(Approximately 4 seconds)
• When a warning has been given