Panasonic MINAS A4P Series User Manual Page 67

  • Download
  • Add to my manuals
  • Print
  • Page
    / 232
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 66
67
[Setting]
Setting
58 0 to 1
<1>
Point specifying 
input logic setting
Set the logic of the point specifying inputs (P1IN to P32IN: CN X5 Pin 3, 4, 5, 6, 7 and 8).
Setup value
0
<1>
Description
Point
specifying
inputs are enabled by opening the connection to COM
.
Point
specifying
inputs are enabled by closing the connection to COM
.
59 0 to 1
<1>
Multi-function 
input 1 Signal logic
Set the logic of the multi function input 1 (EX-IN1: CN X5 Pin 22).
Setup value
0
<1>
Description
Input is enabled by opening the connection to COM
.
Input is enabled by closing the connection to COM
.
5A
*
0 to 6
<0>
Multi-function 
input 1 Signal 
selection
Set the function of the multi function input 1 (EX-IN2: CN X5 Pin 22).
Setup value
<0>
1
2
3
4
5
6
Description
Disabled (regardless of the logic setting in SV.Pr59).
Immediate stop
Temporary stop
Deceleration and stop
High-speed normal rotation jog
High-speed reverse rotation jog
Alarm is cleared.
5B 0 to 1
<1>
Multi-function 
input 2 Signal logic
Set the logic of the multi function input 2 (EX-IN2: CN X5 Pin 25).
Setup value
0
<1>
Description
Input is enabled by opening the connection to COM
.
Input is enabled by closing the connection to COM
.
5D 0 to 1
<1>
Servo-ON input
valid
Specify whether to enable or disable the servo-on input (SRV-ON: CN X5 Pin 23).
5C
*
0 to 6
<0>
Multi-function 
input 2 Signal 
selection
Set the function of the multi function input 2 (EX-IN2: CN X5 Pin 25).
<Note>
The setting of the multi function input 1 and that of the multi function input 2 must be
different from each other. Moreover, if high-speed normal rotation jog and high-
speed reverse rotation jog are assigned to the input 1 and input 2, respectively, the
motor does not work when those turn on simultaneously.
Setup value
<0>
1
2
3
4
5
6
Description
Disabled (regardless of the logic setting in SV.Pr5B).
Immediate stop
Temporary stop
Deceleration and stop
High-speed normal rotation jog
High-speed reverse rotation jog
Alarm is cleared.
Setup value
0
<1>
Description
Disable: 
A servo turns on after the power supply turns on, regardless of the state
of servo-on input (SRV-ON: CN X5 Pin 23).
Enable: 
A servo turns on when the servo-on input (SRV-ON: CN X5 Pin 23) has
been input after the power supply turns on.
Servo
PrNo.
Setup
range
Title Function/Content
Standard default : < >
Page view 66
1 2 ... 62 63 64 65 66 67 68 69 70 71 72 ... 231 232

Comments to this Manuals

No comments